Sizing Requirement Guidelines for Pump Cable 

fog-jet_maxi_photo.jpg (32457 octets)


From the chart below. select the pump's horsepower and then select the distance required from the control panel to the floating fountain unit. Allow for extra-cable length, because the cable will probably run along the bottom of the lake or pond due to the weight of the cable. The code indicated in the chart refers to the cable gauge:

85802  #12/3           85804   #10/3          85806  #8/3           85808  #6/3
85803  #12/4           85805   #10/4          85807  #8/4           85809  #6/4

Please note that the cable has to be
"one continuous run" from the command center to the pump unit. Should the cable wire not be long enough, adding extra cable or additional connections will cause the pump to operate incorrectly or not at all.

Aerator

Cable Lengths up to:

Horsepower

150 ft.

200 ft.

250 ft.

300 ft.

350 ft.

400 ft.

450 ft.

500 ft.

600 ft.

.5hp 85802 85804 85804 85806 85806 85808 85808 85808 85808
.75hp 85802 85802 85802 85802 85802 85802 85802 85804 85804
1.00hp 85802 85802 85802 85802 85802 85802 85804 85804 85804
1.50hp 85802 85802 85802 85802 85804 85804 85804 85806 85806
2.00hp 85803 85803 85803 85805 85805 85807 85807 85807 85807
5.00hp(1ph) 85805 85807 85807 85809 85809 85809 85809 n/a n/a
5.00hp(3ph) 85805 85807 85807 85809 85809 85809 85809 n/a n/a
7.50hp 85805 85805 85807 85807 85809 85809 n/a n/a n/a
10.00hp 85805 85807 85809 85809 85809

n/a

n/a n/a n/a
15.00hp 85807 85809

85809

n/a

n/a

n/a

n/a n/a n/a

 